Q & A
When the output voltage and current of potentiostat reach the maximum, C1 potential indicator drops?
- Author:Libo
- Source:wphotodu.cn
- Date:2021-06-11
- Click:0
Cause of failure: insulation flange short circuit; Or short circuit with other underground metal structures; Treatment method of reference electrode damage: repair short-circuit insulation flange, disconnect underground metal structure; Check the reference electrode measurement line or replace the reference electrode