国产亚洲欧美在线视频_国产一级手机毛片_国产高清精品在线播放_天天操狠狠操夜夜操_少妇喷水久久av_欧美熟妇另类zozo高清_三级无码在线观看_亚洲欧美强伦在线_搡老女人老熟妇HHD_亚洲欧美一区二区高清

Welcome to Jiaozuo Libo Light Alloy Co., Ltd.

Aluminum alloy sacrificial anode

magnesium anode, zinc anode

Telephone:

0391-7588881 +8618739187123

Jiaozuo Libo Light Alloy Co., Ltd.

News

News

Contact

Phone:18739187123

hotline:0391-7588881

E-mail:970512272@qq.com

Address:Wuzhi County, Jiaozuo City, China

Industry News

Cathodic protection with forced current

  • Author:Libo
  • Source:wphotodu.cn
  • Date:2021-06-11
  • Click:0

Forced current measures are very suitable and economical for cathodic protection because anodes are very durable and because anodes come in many shapes and quantities. Only a few examples are presented here. The internal cathodic protection of fuel tanks has been described in Section 11.7, and the internal cathodic protection of water tanks is detailed in Chapter 20.


Internal cathodic protection of aqueous crude oil storage tanks


After secondary and tertiary oil recovery from reservoirs, the oil produced is usually "water-cut crude," which consists of brine and crude oil, associated gas with high CO2 content and, in some cases, a small amount of H2S. Water-cut crude oil always contains solid particles from the formation.


According to the application requirements, water-cut crude oil is collected into a large steel storage tank (separation tank) of 100~10000m3 for processing. In the process of treatment, waste water will be discharged, which is corrosive because of its high salt concentration (1Mo1 /L), high CO2 content (equivalent to 1bar, i.e., 1×105Pa partial pressure), PH value maintained at 6 after buffering with CaCO3, and small amount of H2S and trace amount of O2. The investigation results show that under these conditions and the maximum operating temperature of 70℃, ucU-CUSO4 =-0.95V protection potential must be used. At PH =4 in unbuffered media, the protective potential must be reduced by another 0.1V. If the total current density-potential curve is steep, a correspondingly high protection current requirement must be adopted. The lowest current densities are 10A·mˉ2, but if scaling occurs, they become much smaller.


If the paint is used alone, the anticorrosive layer is required to be perfect and non-destructive, without any pinholes or defects during the use. Because this is difficult to ensure, there is a risk of forming an anticorrosive battery, so it is wise to combine the coating with cathodic protection. The coating selected must be compatible with cathodic protection and must be suitable for operating conditions, and references are given for such decisions. Due to the neglect of cathodic damage of the coating, serious damage of the coating has occurred in the past, resulting in a significant increase in the protection current density. Internal cathodic protection without damage to the anticorrosive coating is possible only with a resinous coating with sufficient resistance and a thickness of more than 800μm. The stability of the coating against cathodic vacuoles can be determined by long-term test and accelerated test, and this characteristic should be verified under actual operating conditions.


Internal forced-current electrochemical protection is usually a niobium anode coated with metal oxide and, in small tanks, a zinc sacrificial anode has also been used; Potential control should be implemented to avoid unacceptable negative potential; To use a pure zinc electrode as a reference electrode for monitoring and controlling the exposed area, such an exposed area must be anodized clean throughout the operation; These reference electrodes were examined with an AG-AGC1 electrode.


Because the electrolyte has a good conductivity, a good current distribution is expected. However, if a large area of corrosion layer damage, due to the low polarization resistance, local under-protection is difficult to avoid, therefore, with multiple electrode control is wise.


Online
聯(lián)系方式

熱線電話

18739187123

上班時(shí)間

周一到周五

公司電話

0391-7588881